Milford Hospital Boiler Room and Heating Distribution Replacement Works
- Published
- 7 January 2026
- Estimated value
- £733,657
- Procedure
- Direct award
- Lots
- 1
- Notice number
- 000910-2026
- Reference
- ocds-h6vhtk-060097
- Official source
- Official source
CPV codes
- 45331110Boiler installation work
Description
The hospital's heating infrastructure comprises two plant rooms: the north room with two 75kW gas boilers serving the X-ray block, and the south room with two 175kW boilers supporting both radiators and air handling units (AHUs). LEDA’s thermal modelling determined a total heating load of around 354kW, prompting a proposed upgrade to 450kW using three 150kW Hamworthy modular boilers. This upgrade will also include new heating and LTHW pumps, a pressurisation unit, expansion vessel, dosing ports, shunt pumps, and a gas safety system, while retaining the existing gas-fired calorifier. The current below-ground pipework serving radiators in both blocks will be replaced by a new system routed through loft areas, with local drops to individual radiators. These radiators will be LST type, each fitted with Danfoss dynamic valves and remote temperature sensors for independent control, eliminating the need for zone valves. Bypass valves will be installed at end-line pipes to ensure minimum flow, and radiant panels will be added to ward areas with grid ceilings and corridors. Pipework drops will be enclosed using Pendock boxing, as detailed in the mechanical services drawings.
Awards
| Awarded to | Amount | Date |
|---|---|---|
| MJG Mechanical Services Ltd | — | — |
Official publications
- FTS · 000910-2026 · 7 January 2026
Other tenders from NHS Property Services Limited
- External remedials at Ramsbottom Health Centre
- Car Park Resurfacing
- Replacement Velux & Windows
- Damp remedials, DB Replacements and External upgrades at Albion Drive Clinic
- External Upgrades and Entrance Flooring Replacement at Guide Lane Medical Centre
- Conway Road Decarbonisation & Drainage at Conway Road Health Centre
- Sneinton Health Centre – Roof Replacement (including Structural Works)
- Ince Clinic Roof & Compartmentation
- Roofing Upgrade Works
- External Repairs and Window Replacement at Maghull Health Centre
Frequently asked questions
- What is the estimated value of this tender?
- The estimated value published by the buyer is £733,657.
- Who is the buyer of this tender?
- The contracting authority is NHS Property Services Limited (United Kingdom).
- How can I bid for public tenders in the United Kingdom?
- Bids are submitted through the official public procurement portal in the United Kingdom. El Vínculo helps you find tenders and analyse their documents; submission always happens at the official source.
Create a free account and receive new public tenders published in the United Kingdom that match your business, every day.