El Vínculo El Vínculo.
Severna Makedonija Скопски
Open European Union Supplies

Medical devices and medical consumables for interventional cardiology – stents and distal embolic protection.

PHI UNIVERSITY CLINIC FOR CARDIOLOGY AND CARDIOVASCULAR SURGERY NATIONAL CENTER FOR CARDIOVASCULAR DISEASES

Open until 23 November 2026.

Interested in tenders like this? Get the next tenders like this one published in the European Union by email. Free, no card needed.

Amounts and figures

26
Lots

Description

Medical devices and medical consumables for interventional cardiology – stents and distal embolic protection.

Lots (26)

LotDescriptionCPV codeAmount
1 Medical devices and medical consumables for interventional cardiology – stents and distal embolic protection.
Skopje, MK008
33000000 Medical equipments, pharmaceuticals and personal care products —
2 Coronary stent with a sinusoidal configuration and a permanent polymer coating containing a cytostatic agent from the “-limus” family (DES), with a platinum-iridium core for enhanced radiopacity, an outer cobalt-chromium layer, and platinum-iridium markers; minimum stent diameter range 2.25–4.0 mm and minimum length range 8–38 mm.
Skopje, MK008
33000000 Medical equipments, pharmaceuticals and personal care products —
3 Coronary stent with a permanent polymer coating containing a cytostatic agent from the LIMUS family (DES), with a platinum-iridium core for enhanced radiopacity, an outer cobalt-chromium layer, and platinum-iridium markers; minimum stent diameter range 2.0–5.00 mm, with overexpansion capability up to 6.00 mm (for 4.5–5.0 mm diameters), and a minimum length range of 8–38 mm.
Skopje, MK008
33000000 Medical equipments, pharmaceuticals and personal care products —
4 Coronary stent designed for the treatment of large-lumen blood vessels, with high radial and axial strength, made of platinum-chromium alloy, abluminally coated with a bioresorbable PLGA polymer and the cytostatic agent everolimus (DES), with a dual-layer balloon system, a diameter range of 3.5–5 mm, and a length range of 8–32 mm. The stent can be further expanded up to a maximum diameter of 6 mm.
Skopje, MK008
33000000 Medical equipments, pharmaceuticals and personal care products —
5 Coronary stent made of platinum-chromium alloy, with a thin stent strut profile ≤81 μm, a non-linear link design with an open-cell configuration, abluminally coated with a bioresorbable PLGA polymer and the cytostatic agent everolimus (DES), with a dual-layer balloon system, a diameter range of 2.25–5 mm, and a length range of 8–48 mm, compatible with a 5F guiding catheter for all sizes.
Skopje, MK008
33000000 Medical equipments, pharmaceuticals and personal care products —
6 Self-expanding cobalt-chromium stent for carotid arteries, compatible with a 0.014" guidewire and a 5F introducer sheath, with a straight and tapered closed-cell design, a diameter range of 6–10 mm, and a length range of 30–50 mm.
Skopje, MK008
33000000 Medical equipments, pharmaceuticals and personal care products —
7 Coronary stent made of cobalt-chromium alloy, with an open-cell design and a biodegradable polymer coating, coated with the immunosuppressive drug sirolimus, with a stent strut thickness of 60 µm, featuring PROBIO coating (amorphous silicon carbide), a diameter range of 2.25–4 mm, and a length range of 9–40 mm.
Skopje, MK008
33000000 Medical equipments, pharmaceuticals and personal care products —
8 Peripheral balloon-expandable stent, made of cobalt-chromium, with an OTW (over-the-wire) system, compatible with a 6F introducer sheath, with a strut thickness of 110 µm (for stents with diameters of 5–7 mm), featuring PROBIO coating, with 2 markers, on a 90, 135, and 170 cm delivery catheter, with a stent length range of 18–78 mm and a diameter range of 5–10 mm.
Skopje, MK008
33000000 Medical equipments, pharmaceuticals and personal care products —
9 Coronary stent made of cobalt-chromium alloy, with a non-linear multi-link cell design, coated with a permanent polymer and the cytostatic agent everolimus (DES), with a diameter range of 2–4 mm and a length range of 8 mm to at least 38 mm, compatible with a 5F guiding catheter for all sizes.
Skopje, MK008
33000000 Medical equipments, pharmaceuticals and personal care products —
10 Coronary stent made of cobalt-chromium alloy, with a multi-link, non-linear link stent design, intended for large-diameter coronary arteries, coated with a permanent polymer and the cytostatic agent everolimus (DES), with a low stent crossing profile of ≤0.039" (for a 3 mm stent diameter), a diameter range of 2.25–4 mm, and a length range of 8–38 mm, with expansion capability up to 5.5 mm for 3.5
Skopje, MK008
33000000 Medical equipments, pharmaceuticals and personal care products —
11 Peripheral nitinol stent system, self-expanding, with a woven mesh design, flexible and kink-resistant, intended for interventions in the femoral and popliteal arteries, with a diameter range of 4.5–7.5 mm and a stent length range of 20–200 mm, compatible with a 6F introducer sheath.
Skopje, MK008
33000000 Medical equipments, pharmaceuticals and personal care products —
12 Self-expanding carotid stent system made of nitinol alloy, with a closed-cell design, an RX system, with a straight or tapered diameter ranging from 6.0 to 10.0 mm and lengths ranging from 20 to 40 mm, compatible with a 6F guiding introducer sheath.
Skopje, MK008
33000000 Medical equipments, pharmaceuticals and personal care products —
13 Distal embolic protection system for carotid artery stenting, featuring technology for independent deployment of a 0.014" guidewire, three levels of wire support, and subsequent deployment of an embolic protection filter with diameters of 5 and 7.2 mm and pore size of at least 120 µm; the system includes a retrieval catheter and is fully compatible with a 6F introducer sheath or a 7F guiding cathe
Skopje, MK008
33000000 Medical equipments, pharmaceuticals and personal care products —
14 Coronary CoCr DES stent designed for long, complex, and bifurcation lesions, coated with a bioresorbable polymer containing a cytostatic agent from the “LIMUS” family, selectively applied to the abluminal surface at 3.9 μg/mm, with an open-cell design, a diameter range of 2.0–4.5 mm, and a length range of 9–50 mm.
Skopje, MK008
33000000 Medical equipments, pharmaceuticals and personal care products —
15 Self-expanding carotid stent made of nitinol alloy, with a flexible, dual-layer micromesh closed-cell design for protection against embolization, with repositioning capability during deployment up to 50%, compatible with a 5F introducer sheath and an RX system, with a stent diameter range of 5–10 mm and a stent length range of 16–40 mm.
Skopje, MK008
33000000 Medical equipments, pharmaceuticals and personal care products —
16 Peripheral stent-graft system, balloon-expandable, indicated for interventions in the renal and/or iliac arteries, consisting of a stainless-steel stent with an open-cell design, fully encapsulated in a single PTFE layer with a controlled pore size of 55 µm, with a diameter range of 5–10 mm and a length range of 16–59 mm, compatible with a 6–7F introducer sheath and a 0.035" guidewire, with cathet
Skopje, MK008
33000000 Medical equipments, pharmaceuticals and personal care products —
17 Coronary stent-graft system, balloon-expandable, made of cobalt-chromium alloy, intended for the management of complications during interventions, with a maximum profile of 1.25 mm, compatible with a 5F catheter for diameters of 2.5–4.0 mm and a 6F catheter for diameters of 4.5 and 5.0 mm, with lengths ranging from 15 to 26 mm.
Skopje, MK008
33000000 Medical equipments, pharmaceuticals and personal care products —
18 Peripheral stent-graft system with high radial strength, indicated for implantation in the iliac and renal arteries for the treatment of aneurysms, acute perforations, acute ruptures, and fistulas. Made of a cobalt-chromium (CoCr) stent covered with a 203 μm ePTFE layer. Balloon-expandable, with a 5F shaft, compatible with a 0.035" guidewire, with diameters ranging from 5–10 mm, lengths ranging fr
Skopje, MK008
33000000 Medical equipments, pharmaceuticals and personal care products —
19 Balloon-expandable covered peripheral stent with a dual ePTFE layer, inner and outer. Made of CoCr alloy, with an open-cell design, featuring three radiopaque markers at each end of the stent and two markers on the balloon. Diameter range: 5–10 mm; length range: 17–57 mm; compatible with a 0.035" guidewire. Catheter lengths: 80 and 140 cm.
Skopje, MK008
33000000 Medical equipments, pharmaceuticals and personal care products —
20 Self-expanding carotid stent made of nitinol, featuring technology designed to prevent plaque prolapse through the stent for permanent embolic protection, with a dual-layer design and an open-cell configuration, with a diameter range of 6–10 mm and a length range of 20–60 mm (for selected diameters).
Skopje, MK008
33000000 Medical equipments, pharmaceuticals and personal care products —
21 Coronary bioadaptor – coronary scaffold composed of three CoCr sinusoidal arrays, coated with a drug and a bioresorbable polymer, designed to unlock the scaffold six months after implantation; diameter range: 2.25–4.0 mm; length range: 14–38 mm.
Skopje, MK008
33000000 Medical equipments, pharmaceuticals and personal care products —
22 Coronary stent system (DES) with everolimus, featuring an ultrathin 50 µm cobalt-chromium L605 platform, coated with a biodegradable and biocompatible polymer that delivers everolimus (LIMUS family) for controlled drug release, with a hybrid cell design, equipped with platinum-iridium radiopaque markers, a rapid-exchange delivery system compatible with a 0.014" guidewire and a 5F guiding catheter,
Skopje, MK008
33000000 Medical equipments, pharmaceuticals and personal care products —
23 Dedicated bifurcation stent system for side branches, with sirolimus (DES) on a 65 µm cobalt-chromium L605 platform, featuring a biodegradable polymer coating (PLGA + PLLA) for controlled drug release (~30 days), with a main-branch anchoring segment with markers for positioning at the carina and ostium (4 platinum-iridium markers), a rapid-exchange delivery system with a step balloon, compatible w
Skopje, MK008
33000000 Medical equipments, pharmaceuticals and personal care products —
24 Tapered stent system for the treatment of long, diffuse lesions using a single stent. Stent material: cobalt-chromium L605 alloy or equivalent; stent strut thickness: 65 µm; drug (active substance): sirolimus; polymer: biodegradable and biocompatible; delivery system: Rapid Exchange (RX) system; drug dose: 1.25 µg/mm². Diameter combinations: 2.75–2.25 mm, 3.00–2.50 mm, 3.50–2.75 mm, and 3.50–3.00
Skopje, MK008
33000000 Medical equipments, pharmaceuticals and personal care products —
25 Cobalt-chromium alloy coronary stent, multi-link, featuring a Peak-to-Valley stent design for the treatment of tapered (conically narrowed) coronary lesions with small and large diameters, coated with a permanent polymer and the cytostatic drug everolimus (DES), with a strut thickness of 81 µm, a diameter range of 2 to 5 mm, and lengths ranging from 8 to 48 mm, with the capability of expansion up
Skopje, MK008
33000000 Medical equipments, pharmaceuticals and personal care products —
26 Peripheral CoCr stent for BTK calcified arteries, coated with sirolimus at 1.4 μg/mm² and a fluoroacrylate trilayer coating, with drug release over 2 months (75% during the first month), open-cell design with alternating links, strut thickness of 75–85 µm, high radial strength, shortening of <3%, pre-mounted on an Rx semi-compliant balloon with a 142 cm catheter, hydrophilic coating, tip profile o
Skopje, MK008
33000000 Medical equipments, pharmaceuticals and personal care products —

Official publications

MediumReferenceDate
TED 00743838-2026 27 October 2026
OJS 208/2026 27 October 2026

Other tenders from PHI UNIVERSITY CLINIC FOR CARDIOLOGY AND CARDIOVASCULAR SURGERY NATIONAL CENTER FOR CARDIOVASCULAR DISEASES

See the buyer →

Similar open tenders

Frequently asked questions

What is the deadline to bid for this tender?
The submission deadline is 23 November 2026, 12:00. Check the official source, as dates can be modified.
Who is the buyer of this tender?
The contracting authority is PHI UNIVERSITY CLINIC FOR CARDIOLOGY AND CARDIOVASCULAR SURGERY NATIONAL CENTER FOR CARDIOVASCULAR DISEASES (European Union).
How can I bid for public tenders in the European Union?
Bids are submitted through the official public procurement portal in the European Union. El Vínculo helps you find tenders and analyse their documents; submission always happens at the official source.

How can I find out about similar tenders when they are published?

Create an account at el-vinculo.com and we give you a free month and set up your company's filters — contract type, CPV codes, value and territory — so you are the first to know when new tenders like this one come out in the European Union. We email you as soon as one matching your profile is published, with the whole deadline ahead to prepare the bid.

No credit card · Sign up in 2 minutes.

Get alerts for tenders like this
Create a free account and receive new public tenders published in the European Union that match your business, every day.

Start for free

Data collected from official public procurement sources. Amounts as published by the buyer.